Manual Launch of DRAGEN TSO 500 Analysis on ICA
Last updated
Last updated
Create a Project: Project can be specific for the DRAGEN TruSight Oncology 500 pipeline or it can contain multiple Pipelines and/or Tools). For information on creating Projects, refer to the Projects section in Illumina Connected Analytics help.
ICA standard storage is used by default as soon as the Project is saved. To connect a different storage source, set it up before creating your Project. For details and options, refer to the Storage section in Illumina Connected Analytics help.
Edit Project and Add Bundle: Edit the Project and add the bundle titled, "DRAGEN TSO 500 v2.6.0 (XX)." XX is a 2-letter code designating the region from which you are launching the analysis. Adding the Bundle automatically adds the pipeline and associated resource files and datasets to the Project. For information on Bundles, refer to the Bundles section in Illumina Connected Analytics help.
After adding the Bundle to the Project, an example dataset becomes available in the Demo_Data folder for the Project.
Upload the sequencing data: For information on viewing and uploading data, refer to the Data section in Illumina Connected Analytics help.
Start Analysis: In the Project, navigate to Pipelines, select the TSO 500 v2.6.0 Pipeline, and then select "Start New Analysis". Set up the new analysis by configuring the parameters listed in the table below. When the required files are completed, start analysis.
Download Results: After analysis is complete, navigate to results in the configured output location.
Please see the Illumina Support Shorts for guidance on how to set up and run DRAGEN TSO 500 RUO analysis on ICA.
To launch an analysis via the ICA user interface, configure a DRAGEN TSO 500 pipeline analysis with the following parameters.
For information about using pipelines, refer to Illumina Connected Analytics support site page.
Parameter Name | Description |
---|---|
User Reference
The analysis run name.
User Tags
Text labels to help index the analysis.
Notify me when task is completed
Option to receive an email notification when analysis is complete.
Output Folder
The path to the analysis output folder. The default path is the project output folder.
Entitlement Bundle
Automatically populated from the project details.
Sample Sheet
Select a sample sheet in CSV format for the analysis.
To note: Sample Sheet selection is optional if starting from a run folder, and required when submitting a FASTQ folder.
Input Folder
The run folder or FASTQ folder that contains files to analyze.
FASTQ List CSV
Do not use, this only applies to auto-launch TSO 500 analysis from FASTQs after BCL auto-launch.
Starts from FASTQ
True for analysis performed on files in the FASTQ folder. False for analysis performed on files in the run folder.
Sample or Pair IDs
Optional subset of Sample IDs or Pair IDs to analyze.
Sample List
Do not use, this only applies to auto-launch TSO 500 analysis from FASTQs after BCL auto-launch.
Storage Size
The storage size to allocate for the analysis. The default and recommended value is Large.